Telemetry system components
http://www.sensortelemetrie.de
non-contact, high-precision, modular
Telemetry components
https://www.sensortelemetrie.de/en/products/telemetry-systems/telemetry-products-and-components/
Sensors
Record the variable to be measured and transmit this as a raw measured value to the measuring amplifier
Measuring amplifier
Prepare the signal for transmission. The signal is digitized and error compensated.
Transmission
Inductively, via a high-frequency electric field, using a rotor and stator antenna.
Evaluation unit
Data reception by a stator antenna. Data is demodulated and checked.
Data reception
Data transfer for recording or remote configuration of the measuring chain to a PC.
Sensors
We, the MANNER Sensortelemetrie GmbH, combine various sensors with our sensor telemetry system. This means that we select the suitable sensor for the variable to be measured together with the customer. Either this is done as a side order or as supply by us.
Our multifunctional systems can be adapted to almost any sensor. A selection of typical applied sensors is mentioned here as an example. This is not a complete list of available sensors.
- Strain gauges in ¼-, ½-, and full bridge circuit (recording of strains, manufacture of measuring elements for recording axial force, bending moment, torque …)
- Accelerometers
- Pressure sensors
- Temperature sensors (PT100, TC, others)
- Inductive displacement sensors
- Speed sensors
- Bearing encoder
- Angle encoder
Measuring amplifier
SV-Flex – Sensor Signal Amplifier Type Samy Flex
For strain gage
Measuring range up to 1000°C
Bandwidth: up to 500 Hz with 1 channel, up to 100 Hz with 16 channels
Data sheet
STEP Data
Manual
SV-Flex – Sensor Signal Amplifier Type Kalimero
For thermocouple (isolated or non-isolated), Pt100, strain gage
Measuring range up to 1000°C
Bandwidth: up to 500 Hz with 1 channel, up to 100 Hz with 16 channels
Data sheet
STEP Data
Manual
SV2a – Sensor Signal Amplifier Type 2a
(with integrated Rotor Antenna)
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV2b – Sensor Signal Amplifier Type 2b
(with integrated Rotor Antenna)
End of shaft, Cartridge, Turbine, Integrated Rotor Coil
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV2bx – Sensor Signal Amplifier Type 2bx
(with integrated Rotor Antenna)
End of shaft, Cartridge, Turbine, Integrated Rotor Coil
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV2c – Sensor Signal Amplifier Type 2c
(with integrated Rotor Antenna)
End of shaft, Miniatur Cartridge, Turbine
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV2d – Sensor Signal Amplifier Type 2d
(with integrated Rotor Antenna)
End of shaft, Miniatur Cartridge, Turbine
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP-Datei
Manual
SV2La – Universal Shaft Transmitter with Sensor Signal Amplifier Type 2La
non dividable, 1 channel, with/without RMC, without rpm sensor
Beared wheel transmitter
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 10 kHz
Data sheet
STEP Data
Manual
SV2Lg – Universal Shaft Transmitter with Sensor Signal Amplifier Type 2Lg
dividable, 1 channel, with/without RMC, without rpm sensor
Beared wheel transmitter
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 10 kHz
Data sheet
STEP Data
Manual
SV3a – Sensor Signal Amplifier Type 3a
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV3b – Sensor Signal Amplifier Type 3b
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV3c – Sensor Signal Amplifier Type 3c
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV4a – Sensor Signal Amplifier Type 4a
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV4b – Sensor Signal Amplifier Type 4b
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV5a – Sensor Signal Amplifier Type 5a
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV5b – Sensor Signal Amplifier Type 5b
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV5c – Sensor Signal Amplifier Type 5c
Miniature Patrone
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV5d – Sensor Signal Amplifier Type 5d
Super Miniature Patrone
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 1 kHz
Data sheet
STEP Data
Handbuch
SV7a – Miniatur Sensor Signal Amplifier Type 7a
Flatchip
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV7b – Super Miniatur Sensor Signal Amplifier Type 7b Micro
Flatchip
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 10 kHz
Data sheet
STEP Data
Manual
SV7ke – Miniatur Sensor Signal Amplifier Type 7ke
Flatchip with integrated Antenna (special for Chain Application)
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV8a – Waterproof Sensor Signal Amplifier Type 8a
Transmitter with Antenna
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
SV9 – Sensor Signal Amplifier Type 9
Transmitter with Antenna especially for Driveshaftes
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz
Data sheet
STEP Data
Manual
Transmission units
Pickup Type 2
Pickup Type 3
customizable
Data sheet
STEP Data
Manual
Pickup Type 4b
Pickup Type 5a
Pickup Type 5b
Pickup Type 5d
Pickup Type 5x
Pickup Type 8a
Pickup Type 8b
Pickup Type 8c
Pickup Type 8d
Pickup Type 8e
Pickup Type 8f
Pickup Type 9c
Pickup Type 9d
Pickup Type 9e
Universal Shaft Transmitter
non dividable
without Amplifier
Data sheet
STEP Data
Manual
Evaluation units
AW_D – Evaluation Unit (integrated Pick Up)
1 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary
RF power: 1 W, 3 W
Data sheet
STEP Data
Manual
OptiMA – Evaluation Unit
außerordentlicheÜbertragungsreichweite bis zu 50mm
1 to 2 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary
RF power: 3 W
Data sheet
STEP Data
Manual
AW_M – Evaluation Unit
1 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary
RF power: 1 W, 3 W
Data sheet
STEP Data
Manual
AW_P – Evaluation Unit
1 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary, USB, CAN
RF power: 1 W, 3 W, 5W
Data sheet
STEP Data
Manual
MAW_F – Evaluation Unit Digital Receiver
1 to 64 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA option
Digital interface (option): USB, Ethernet (TCP/IP), EtherCAT
Data sheet
STEP Data
Manual
AW42TE – Evaluation Unit (42TE)
Multi Channel PCM Receiver 42 TE
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB
Data sheet
STEP Data
Manual
AW84TE – Evaluation Unit (84TE, 3HE)
Multi Channel PCM Receiver 84 TE
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB
Data sheet
STEP Data
Manual
AW84TE – Evaluation Unit (84TE, 6HE)
Multi Channel PCM Receiver 84TE HE6
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB
Data sheet
STEP Data
Manual
AW_ES_MGC – Evaluation MGC Plugin Unit
1 Channel MGC-Plugin Unit PCM Receiver
Bandwidth: 0 t 1 kHz
Output: 5 to 15 kHz
RF power: 3 W
Data sheet
STEP Data
Manual
AW_ES – Evaluation Unit
Multi Channel PCM Receiver ES
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB
Data sheet
STEP Data
Manual
Data reception
MANNER offers its customers tailor-made software for their telemetry systems. This enables them to make the necessary settings themselves – conveniently via their PC.